How much power a boiler uses
Electricity runs the boiler’s controls, the circulation pump and, in a turbo boiler, the fan as well. Together it is not much: our calculator counts a boiler with pumps as 0.12 kW on average and up to 0.3 kW at start-up. The exact electrical power is given in the boiler’s manual.
Which inverter it needs
Even the smallest inverter has enough power, so other things matter more. First, a pure sine wave at the output: the boiler’s electronics and pump are designed for it. Second, a fast switch to the battery when the power goes out: the Bluesun 4.2 kW switches in 10 ms in its computer mode and in 20 ms in its appliance mode.
For a boiler alone, the Bluesun 4.2 kW for 24 V at 14,000 ₴ with a 25.6 V battery will do. If a fridge, lights and internet, or even a well pump, should run along with the boiler, take a 48 V inverter: the Bluesun 5.5 kW at 23,000 ₴ also gives a pure sine wave and typically switches in 10 ms. How hybrid inverters with and without grid export differ: a hybrid inverter with or without grid export.
Many boilers are phase-sensitive: they only start when phase and neutral are connected the right way round and there is an earth. So it is best to have an electrician connect the inverter to the boiler.
How many hours of heating a battery gives
Bluesun 25.6 В 2.66 kWh 17 h 17 h
Bluesun 25.6 В 5.3 kWh 35 h 35 h
Felicity 8.75 kWh 65 h 65 h The battery’s energy divided by the average power, rounded down: for the 25.6 V batteries 80% of the energy, the depth of discharge their 6000 cycles are rated at; for the Felicity 8.75 kWh 90% of the energy, a little less than the 95% depth of discharge in its datasheet. The inverter uses power too, and with such a small load it shows, so in practice there will be fewer hours.
A 2.66 kWh battery runs the boiler and pumps alone for about 17 hours, a night without power. For longer outages, or to run a fridge and lights as well, take 5 kWh or more. How to count the hours for other appliances: how long a house runs on a battery.
Charging and where to install
While there is power, the inverter charges the battery from the grid, and with panels from the sun as well: the Bluesun 4.2 kW takes up to 6.2 kW of panels. The 25.6 V batteries are best charged at up to 50 A (2.66 kWh) and up to 100 A (5.3 kWh), so from empty they charge in about two hours.
The Bluesun 25.6 V batteries have a heater and charge in frost down to −20 °C, in an IP65 case. The inverter is rated for −10 … +50 °C with IP21 protection, so it goes in a dry room.