ESS Bluesun 30 kW / 54 kWh BSE30KH3-54KWH
Model BSE30KH3-54KWH · Bluesun Solar
Excl. VAT. Price in hryvnias at today’s NBU rate
Equipment for business: we agree the supply and installation for your project.
How to order
- A request or a callwe reply within a working day
- An offer for your projectequipment, delivery and lead times
Installation and delivery
- Installation and connectionby our own crew
- Delivery to the siteagreed separately
Questions about the product: +38 067 444 34 34, Mon–Fri, 9:00–18:00
A ready-made kit for a commercial site with a daily consumption of 100–200 kWh: a 30 kW hybrid inverter, ten 51.2 V 106 Ah battery modules, a high-voltage control cabinet, a rack and Wi-Fi monitoring. Everything is tested at the factory; on site you need cable, panels and the grid connection.
The system works as a 30 kW backup with a 10 ms transfer, cuts peak consumption, and charges from up to 45 kW of panels or from the grid at the night tariff. The battery is rated for 6000 cycles at 90% depth of discharge.
Outdoor IP56 design, operating temperature from −10 °C.
- Everything in one rack
- 30 kW backup in 10 ms
- Outdoor IP56 design
System
| Rated output power | 30 kW |
|---|---|
| Battery capacity | 54.2 kWh |
| Battery type | LiFePO4, 10 modules 51.2 V 106 Ah |
| Backup power | 30 kW |
| Protection class | IP56, outdoor design |
| Operating temperature | −10 … +55 °C |
| Communication | Wi-Fi, GPRS, 4G |
| Warranty | 3 years |
BSE30KH3 inverter
| Max. PV power | 45 kW |
|---|---|
| Max. PV voltage | 1000 V |
| MPPT range | 150–1000 V |
| Start-up voltage | 150 V |
| MPPT / strings | 2 / 4 |
| Max. PV input current | 2 × 40 A |
| Max. PV short-circuit current | 2 × 60 A |
| Phases | 3, 230/400 V, 50/60 Hz |
| Max. charge/discharge power | 30 kW |
| Max. charge/discharge current | 60 A |
| Dimensions (H × W × D) | 558 × 535 × 260 mm |
| Weight | 36 kg |
Battery
| Module | BSM48106, 51.2 V 106 Ah |
|---|---|
| Module capacity | 5.4 kWh |
| Usable module capacity | 4.86 kWh |
| Number of modules | 10 |
| Rated voltage | 512 V |
| Max. charge/discharge current | 100 A |
| Depth of discharge | 90% |
| Number of cycles | > 6000 |
Typical solar plant configuration per the datasheet
| Modules | 64 × 565 W, 4 strings of 16, 35.84 kW |
|---|---|
| DC cabinet | 4 inputs / 4 outputs, 1000 V |
| Scope of supply | Control cabinet, rack, Wi-Fi, MC4, PV1-F 4 mm² cable, mounting |