A system for industrial enterprises and energy trading: a 125 kW PCS, a 261 kWh battery on five LiFePO4 modules and an EMS control system in one IP66 cabinet. Liquid cooling keeps the cells at an even temperature, so the cabinet works from −30 to +55 °C and preserves the battery's cycle life.
Inside: a fire suppression system, smoke and temperature sensors, a high-voltage control cabinet, an emergency stop, a built-in chiller. Several cabinets connect in parallel for systems of megawatt-hours; the largest system we have assembled on this platform is 4 MWh.
EMS modes: peak shaving and valley filling, load management, self-consumption from a solar plant, UPS. Data access through the Bluesun ESS cloud over 4G, 5G or LAN. Also supplied in a version with the BSE125KH3 hybrid inverter for direct connection of a solar plant.
- Liquid cooling, IP66
- Fire suppression and EMS included
- Parallel connection of cabinets
- Cloud monitoring 4G / 5G / LAN
General parameters
| Battery configuration | 1P260S, 5 modules of 52.249 kWh |
|---|---|
| Rated energy | 261 kWh |
| Rated voltage | 832 V DC |
| Voltage range | 728–910 V DC |
| Operating temperature | −30 … +55 °C |
| Protection class | IP66 |
| Cooling | Liquid, built-in chiller |
| Coolant | 50% aqueous ethylene glycol solution |
| Communication | RS485, CAN, Ethernet |
| Battery operating voltage range | 615–950 V (3W+PE) / 650–950 V (3W+N+PE) |
| Range at full load | 615–950 V (3W+PE) / 680–950 V (3W+N+PE) |
AC side, grid mode
| Rated voltage | 230 / 400 V, deviation ±15% |
|---|---|
| Output type | 3W+PE or 3W+N+PE |
| Rated output power | 125 kW |
| Maximum output power | 138 kW |
| Maximum current | 200 A |
| Frequency | 50 / 60 Hz |
| Power factor | 0.99, range 1 leading – 1 lagging |
| THDi at rated power | < 2% |
| DC component | < 0.5% |
| Overload | 110% continuous |
| Maximum efficiency | 98.5% |
AC side, off-grid mode
| Rated voltage | 230 / 400 V |
|---|---|
| Voltage harmonics | < 3% at linear load |
| Frequency | 50 / 60 Hz |
| Rated output power | 125 kW |
| Maximum apparent power | 138 kVA |
| Maximum output current | 200 A |
Dimensions and safety
| Dimensions (W × D × H) | 1320 × 1005 × 2200 mm |
|---|---|
| Packed dimensions | 1410 × 1200 × 2380 mm |
| Weight | 2465.5 kg (2589 kg packed) |
| Cell certification | UN38.3, IEC, UL |
| Rack certification | UN38.3, IEC, CE |
| Fire safety | Built-in fire suppression system, smoke and temperature sensors |
| Control | EMS, high-voltage control cabinet, emergency stop |
| BMS | Three-level: CSC on the module, SBMU on the rack |